Description
1. Measuring sensor 5. Large display with colour-coded indicator lights
2. Extra gentle exible tip 6. Battery compartment cover (back)
3. On/O button (side) 7. Protective cap
4. Age Precision™ button
Warnings and Precautions
• YourBraunDigitalThermometerisa3-in-1thermometersuitableforunderarm,oralorrectaluse.
Whichevermethodisused,itisrecommendedthatfor15minutespriortouse,avoideatingordrinking
anyliquids,exercising,takingshowersorbaths,orsmoking.
• Thisthermometerisintendedforhouseholduseonly.Thisproductisnotintendedtodiagnoseany
disease,butisausefulscreeningtoolfortemperature.Useofthisthermometerisnotintendedasa
substituteforconsultationwithyourphysician.
• TheAgePrecision™featureisnotintendedforpre-termbabiesorsmall-for-gestationalagebabies.The
AgePrecision™featureisnotintendedtointerprethypothermictemperatures.
• Pleaseconsultyourphysicianifthethermometershowselevatedtemperature.High,prolongedfever
requiresmedicalattention,especiallyforyoungchildren.
• Parents/guardiansshouldcallthephysicianuponnoticinganyuntowardsign(s)orsymptom(s).For
example,achildwhoexhibitsirritability,vomiting,diarrhea,dehydration,changesinappetiteor
activity,evenintheabsenceoffever,orwhoexhibitsalowtemperature,maystillneedtoreceive
medicalattention.Childrenwhoareonantibiotics,analgesics,orantipyreticsshouldnotbeassessed
solelyontemperaturereadingstodeterminetheseverityoftheirillness.
• TemperatureelevationasindicatedbyAgePrecision™maysignalaseriousillness,especiallyin
neonatesandinfants,oradultswhoareold,frail,haveaweakenedimmunesystem.Pleaseseek
professionaladviceimmediatelywhenthereisatemperatureelevationandifyouaretaking
temperaturefor:
- Neonatesandinfantsunder3months.Consultyourphysicianimmediatelyifthetemperature
exceeds37.4°Cor99.4°F.
- Patientsover60yearsofage.Fevermaybebluntedorabsentinelderlypatients.
- Patients having diabetes mellitus or a weakened immune system
(e.g.HIVpositive,cancerchemotherapy,chronicsteroidtreatment,splenectomy).
- Patients who are bedridden
(e.g.nursinghomepatient,stroke,chronicillness,recoveringfromsurgery).
- Atransplantpatient(e.g.liver,heart,lung,kidney).
• Donotallowchildrenunder12yearsofagetotaketheirtemperaturesunattended.
• Donotallowchildrentowalkorrunduringtemperaturetaking.
• Thisthermometercontainssmallpartsthatcanbeswallowedorproduceachokinghazardtochildren.
Alwayskeepthethermometeroutofchildren’sreach.
• Donotmodifythisequipmentwithoutauthorizationofthemanufacturer.
• ManufacturingdateisgivenbytheLOTnumberlocatedatthebackofthethermometer.Therstthree
(3)digitsrepresenttheJuliandatethattheproductwasmanufactured,andthenexttwo(2)digits
representthelasttwonumbersofthecalendaryeartheproductwasmanufactured.Thelastidentiers
arethelettersthatrepresentthemanufacturer.
• Anexample:LOT:11614FAMimpliesthisproducthasbeenmanufacturedonthe116thdayofthe
year 2014.
What is new about Braun Age Precision™ Thermometer?
• Clinicalresearchshowsthedenitionoffeverchangeswithage
1
.Forexample,whatisanormal
bodytemperatureina4yearold,mayberegardedasafeverinanewborn.Braun’sAgePrecision™
thermometerisanageadjustablethermometerwithapatentedFeverInsight®colour-codeddisplay.
Itusesmedicalguidelinestointerprettemperatureandtakestheguessworkoutofinterpreting
temperaturefortheentirefamily.
• Temperaturereadingsvarydependingonthesiteofmeasurement.Anoraltemperatureisgenerally
0.1°C higher than underarm (axillary) temperature and rectal temperature is generally 0.6°C higher than
underarm temperature.
1,2
Braun’s Age Precision™ feature is optimized for underarm temperature taking.
• Temperaturereadingsvaryfrompersontoperson.Thebestmethodtodetermineyourownnormal
temperatureistousethethermometerwhenyouarefeelingwell.Recordyourreadingtwiceaday
(earlymorningandlateafternoon).Taketheaverageofthetwotemperatures.Thisisconsideredyour
normalbodytemperature.Anyvariationfromitmayindicatesomesortofillnessandyoushould
consult your physician.
Itisimportanttorememberfeverisasymptom,notadisease,andisjustoneofthemanypossiblesignsof
illness.Ifyourchildexhibitssignsofaseriousillness,contactyourphysician
How to Use Your Braun Age Precision™ Thermometer
3 Simple Steps:
1. Switch on the thermometer by pressing the On/O button
Youwillhearashortbeepanddisplaysegmentcheckwillbeperformed.Afterthesegmentcheck,last
temperaturereadingwillbedisplayedfor2seconds.Subsequently,theageiconsandagerangewill
cycle,untiltheAgePrecisionbuttonispressed.
2. Select the age by pressing the AgePrecision™ button
WhentheAgePrecision™buttonispressed,theagerangeiconswillstopcycling,andstopontheage
range icon that was showing when the button was pressed. Keep pressing the button until the desired
agesettingisdisplayed.Thethermometerhas3agesettings:
• 0-3months
• 3-36months
• 36monthsuptoanadult
Aftertheageisselected,theagerangeiconremainssteadilylit.
Thedisplaywillshowthreedashedlinesandthethermometer
is ready to start the measurement.
3. Take the measurement by placing it on the measurement site.
Oncetemperatureriseisdetectedbythermometerinmeasurementmode,itwillbegintomeasure.
Ifthethermometerdoesn’tmeasureatemperaturerise,theageiconandthreedashedlineswillbe
shown until the thermometer automatically turns o.
Aftermeasurement(generally8secondsaftertemperaturechangeisdetected),theconrmation
beepindicatesthatanaccuratetemperaturemeasurementhasbeentaken:1longbeepfornormal
temperature,10shortbeepsforelevatedandhightemperature.Theresultwillbeshownonthe
display.InterpretthereadingwiththehelpofthecolourcodedFeverInSight®displaythatusesmedical
guidelinestointerprettemperaturebasedontheageofthepatients.
Note:Usershavetoshutdownthethermometerandstartupagaintotakeanothermeasurementand/or
changeagesetting.TheBraunAgePrecision™thermometerturnsoautomatically
20secondsafterthemeasurementorafter90secondswithoutmeasurement.
Reading the measurement with Fever InSight® Colour Coded Display
BraunAgePrecision™ThermometercomeswiththepatentedFeverInSight®displaythatoersacolour
indication along with the temperature readout and helps you better understand the temperature reading
basedonpatients’age.
- Green backlight indicates normal reading
- Yellowbacklightindicateselevated temperature
- Redbacklightindicateshigh temperature
TheFeverInSight®colourcodeddisplayforinterpretingfeverhasbeendesignedforuseintheunderarm
mode only according to the table below.
Site Age range
Green
Normal temperature
Yellow
Elevated temperature
Red
Hightemperature
Underarm
0-3 Months
35.7 – 37.3 °C > 37.3 °C
3-36 Months
35.3 – 37.4 °C 37.5–38.4°C >38.4°C
36 Months-
adult
35.3 – 37.4 °C 37.5 – 39.4 °C > 39.4 °C
Ifyouusethethermometerintheoralorrectalmodebyplacingitatthosesites,pleasedonotusethe
displaylightsprogrammedintothethermometerfordeterminingfever.Instead,refertotheoralandrectal
tablesrespectivelyasshownbelowtodetermineifyouhaveafever.
Site Age range
Normal temperature Elevated temperature High temperature
Oral
0-3 Months
35.8–37.4°C > 37.4 °C
3-36 Months
35.4 – 37.6 °C 37.7–38.5°C >38.5°C
36 Months
to Adult
35.4 – 37.7 °C 37.8-39.4°C > 39.4 °C
Rectal
0-3 Months
36.3 – 37.9 °C > 37.9 °C
3-36 Months
35.9–38.1°C 38.2–39.0°C > 39.0 °C
36 Months-
adult
35.9–38.2°C 38.3–39.9°C > 39.9 °C
Note:Duetohumanphysiology,temperaturemeasurementstakenfromdierentsitesonthesame
personshowvariability.Forexample,rectalreadingstendtorunhigherthanoralaswellasunderarm
readingstakenfromthesameperson.
Tips for Measuring at Dierent Sites
Under-the-arm (axillary) use
Thismethodisusedforbabiesandyoungchildren.
1. Wipe the underarm with a dry towel.
2.Placetheprobetipunderthearmsothetipistouchingtheskinandpositionthepatient’sarmnextto
thepatient’sbody(Fig.1).
Withayoungchild,itissometimeshelpfultohugthechildtokeeptheirarmnexttotheirbody.This
ensures that the room air does not aect the reading.
3.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
4.Turnothethermometerandcleanasrecommendedbelow.
Fig.1 Fig.2
Oral use
Thismethodissuitableforchildrenwhoareoldenoughtosafelykeepthethermometerinsidethemouth.
1.Itisimportanttoplacethetipofthethermometerwellunderthetongueoneithersidetogetagood,
accuratereading.Placesensortipinareasmarkedwith“√”underthetongue(Fig.2).Keeppatient’s
mouth closed and make him/her sit still to help ensure an accurate measurement.
2.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
3. Turnothethermometerandcleanasrecommendedbelow.
Rectal use
Commonlyusedforbabies,youngchildren,orwhenitisdiculttotakeanoralorunderarmtemperature.
1.Coverthethermometer’stipwithaprobecoverandlubricatewithawater-solublejellyforeasier
insertion.
Donotuseapetroleumjelly.Readthelabelofthelubricanttobesureyouareusingtherightkind.
2.Laythepatientonhis/herside.Ifthepatientisaninfant,theproperpositionforababyistolayonits
stomachwithlegshangingdown,eitheracrossyourkneesorattheedgeofabedorchangingtable.
Thispositionstheinfant’srectumforsafeandeasyinsertionofthethermometer.
3.GentlyinsertthetipofthethermometerNO MORE THAN1.3cmor1/2inchintotherectum.Ifyou
detectresistance,stop.Holdthethermometerinplaceduringmeasurement.
4.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
5.Turnothethermometerandcleanasrecommendedbelow.
Memory
Whenthethermometeristurnedon,thedisplaywillshowatest,afterwhichthelastmeasured
temperaturewillbeshownforapproximately1second.Letter“M”willbedisplayednexttothe
temperature reading.
Changing the Temperature Scale
Withpowero,pressandholdtheOn/Obuttonforabout5secondsuntil“---“withasteady“°C”or
“°F”appearsonscreen.ReleaseandpresstheOn/Obuttonagaintoswitchfromthecurrentscaletothe
alternatescaleandrelease.Afterabout3secondstheunitisreadyfortakingtemperatureinthechosen
scale and the age range icons start to scroll.
Care and Cleaning
• Cleantheprobetipbywashingwithsoapandwarmwaterorbydisinfectingwithrubbingalcohol(70%
isopropyl alcohol).
• Wipedrywithsoftcloth.
• DO NOT BOIL OR CLEAN IN DISHWASHER.Thiswillcausethethermometertonolongerfunctionand
will void the warranty.
• Donotwashtheunitwithanythinnerorchemicalsolvent
• Storeyourthermometerinadrylocation,freefromdustandcontaminantsandawayfromdirect
sunlight
Replacing the Batteries
WhenthebatterysymbolonLCDdisplaytwinklescontinually replace with new battery.
1.Insertcoinintoslot.RotatedooruntilslotislinedwithUNLOCKsymbol.
2.Replacebattery
3.RotatebatterydoortoLOCKEDposition.
Errors and Troubleshooting
Whenmeasuredtemperatureishigherthan42.9°C,LCDwilldisplay“Err°C”
andrelevantageicon.Redbacklightstaysonfor5seconds.
Whenambienttemperatureisoutofrange(seeProductSpecicationsbelow)
orothersystemerrorsoccursuchasshortorbrokencircuit,LCDwilldisplay“Err
toindicatesystemerror.Redbacklightstaysonfor5seconds.
Limited Two Year Warranty
Kazwarrantsthisproductagainstanydefectsthatareduetofaultymaterialorworkmanshipforaperiod
oftwoyearsfromtheoriginaldateofconsumerpurchaseorreceiptasagift.Thiswarrantyapplieswhen
usedfornormalhouseholduseinaccordancewiththeUseandCareManualandexcludesthebatteryand
damagetotheproductresultingfromaccidentormisuse.Thisproductisnotwarrantedwhenusedina
professionalenvironment.
InnoeventshallKazbeliableforanyspecial,incidental,indirectorconsequentialdamagesinconnection
withthepurchaseoruseofthisproductorcostsovertheoriginalcostofproduct.
Iftheproductshouldnotperformtospecicationswithinthewarrantyperiod,pleasecontactConsumer
Relationsat1-800-477-0457oremailatconsumerrelations@kaz.comorwritetoKazUSAInc,Consumer
RelationsDepartment,250TurnpikeRoad,Southborough,MA01772.InCanada,youcancontactus
at510BronteStreetS,Milton,ON,L7T2X6,Canada.Kazreservestherighttoreplaceanonconforming
productwiththemostcomparableproductcurrentlyavailable.Thisproducthasaveyearminimum
expectedlifetime.
Product Specications
Displayedtemperaturerange: 32.0°C-42.9°C(89.6°F-109.2°F)
Operatingambienttemperaturerange: 10–40°C(50–104°F)
andrelativehumidityrangeof15%~95%
Displayresolution: 0.1°Cor°F
Accuracyfordisplayedtemperaturerange MaximumLaboratoryError
35°C–42°C(95.9°F–107.6°F): ±0.1°C(±0.2°F)atanambientof23±5°C
outsidethisrange: ±0.2°C/0.4°F(within32.0°C-42.9°C(89.6°F-109.2°F))
Batterylife: 500timesmeasurementswithin2years
Servicelife: 2000measurements
Storage/Transporttemperature -25-55±2°Cand15-95RH%±5%
and relative humidity
Ifthedeviceisnotusedwithinspeciedtemperatureandhumidityrangesthetechnicalaccuracyofthe
measurement cannot be guaranteed.
Explanation of symbols
TypeBFappliedparts Seeinstructionforuse
Operating temperature Storagetemperature
Keep dry
IP22:Protectedagainstsolidforeignobjectsof12.5mmdiameterandgreater.Protectedagainstvertically
fallingwaterdropswhenthedeviceistiltedupto15degrees.
Thisthermometerisspeciedtooperateat1atmosphericpressureorataltitudeswithanatmospheric
pressure up to 1 atmospheric pressure (760-1060 hPa).
SeeInstructionforuseEquipmentwithtypeBFappliedparts
Subjecttochangewithoutnotice.
Thisapplianceconformstothefollowingstandards:
StandardReferenceEditionTitle:EN12470-3:2003Clinicalthermometers-Part3:Performanceofcompact
electrical thermometers (non-predictive and predictive) with maximum device.
EN60601-1:2006Medicalelectricalequipment–Part1:Generalrequirementsforbasicsafetyand
essentialperformance.

English

Français

GB
FR
Guidanceandmanufacturer’sdeclaration–electromagneticemissions
ThePRT2000equipmentisintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuserofthePRT2000shouldassurethatitisusedinsuchanenvironment.
Emissions Test Compliance Electromagnetic environment – guidance
RFEmissions
CISPR11
Group 1
TheMEequipmentusesRFenergyonlyforit’sinter-
nalfunction.Therefore,itsRFemissionsareverylow
andarenotlikelytocauseanyinterferenceinnearby
electronic equipment.
RFEmissions
CISPR11
Class B Complies
HarmonicemissionsIEC
61000-3-2
Not Applicable
TheMEequipmentis
solely battery powered.
Voltageuctuations/
icker emissions
Not Applicable
Non-Life Support Equipment Separation Distance Calculation
(3Vrms / 3V/m compliance)
Ratedmaximumoutput
poweroftransmitter(W)
Separationdistanceaccordingtofrequencyoftransmitter(m)
150kHzto80MHzin
ISMbands
80MHzto800MHz 800MHzto2.5GHz
d = [
7
] P
E
1
0.01 / 0.12 0.23
0.1 / 0.38 0.73
1 / 1.2 2.3
10 / 3.8 7.3
100 / 12 23
d = [
3,5
] P
V
1
d = [
3,5
] P
E
1
Guidance and manufacturer’s declaration – electromagnetic immunity
ThePRT2000isintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuserofthePRT2000shouldassurethatitisusedinsuchanenvironment.
Immunity test
IEC60601 test
level
Compliance
level
Electromagnetic environment
– guidance
Electrostatic discharge
(ESD)
IEC61000-4-2
±6kVContact
±8kVAir
Complies
Floorsshouldbewood,concrete,
orceramictile.Ifoorsare
coveredwithsyntheticmaterial,
the relative humidity should be
atleast30%
RadiatedRF
IEC61000-4-3
3V/m80MHzto
2.5GHz
Complies
Fieldstrengthsoutsidethe
shieldedlocationfromxedRF
transmitters,asdeterminedby
anelectromagneticsitesurvey,
shouldbelessthan3V/m.
Interferencemayoccurinthe
vicinityofequipmentmarked
withthefollowingsymbol:
Separationdistancecalculation
providedabove.Ifaknown
transmitterispresentthespecic
distance can be calculated using
the equations.
ConductedRF
IEC61000-4-6
3Vrms150kHzto
80MHz
Not Applicable
(no electrical
cabling)
Electricalfasttransient
IEC61000-4-4
±2kVpowerline
±1kVI/Olines
Not Applicable
TheMEequipment
is solely battery powered.
Surge
IEC61000-4-5
±1kV
dierential
±2kVcommon
Not Applicable
Powerfrequency
magneticeld
IEC61000-4-8
3 A/m Complies
Powerfrequency
magneticeldsshouldbeat
levelscharacteristicofa
typical location in a typical
commercial or hospital
environment.
Voltagedips,short
interrupts and voltage
variations on power
supply input lines
IEC61000-4-11
>95%dip0.5
cycle
60%dip5cycles
70%dip25cycles
95%dip5sec.
Not Applicable
TheMEequipment
is solely battery
powered.
ENISO14971:2012Medicaldevices–Applicationofriskmanagementtomedicaldevices.
ENISO10993-1:2009Biologicalevaluationofmedicaldevices–Part1:EvaluationandTesting.
EN60601-1-2:2007Medicalelectricalequipment–part1-2:Generalrequirementsforbasicsafetyandes-
sentialperformance–Collateralstandard:electromagneticcompatibility–Requirementsandtests
EN980:2008Symbolsforuseinlabelingofmedicaldevices.
EN1041:2008Informationsuppliedbythemanufacturerofmedicaldevices.
EN60601-1-11:2010Medicalelectricalequipment--Part1-11:Generalrequirementsforbasicsafetyand
essentialperformance--Collateralstandard:Requirementsformedicalelectricalequipmentandmedical
electrical systems used in the home healthcare environment.
ThisproductconformstotheprovisionsoftheECdirective93/42/EEC.
MEDICALELECTRICALEQUIPMENTneedsspecialprecautionsregardingEMC.Fordetaileddescriptionof
EMCrequirementspleasecontactourConsumerRelationsDepartment.
PortableandmobileRFcommunicationsequipmentcanaectMEDICALELECTRICALEQUIPMENT.
Pleasedonotdisposeoftheproductinthehouseholdwasteattheendofitsusefullife.Disposal
can take place at your local retailer or at appropriate collection points provided in your country.
Toprotecttheenvironment,disposeofemptybatteriesatappropriatecollectionsitesaccordingto
national or local regulations.
1
HerzogL,PhillipsSG.Addressingconcernsaboutfever.ClinPediatr(Phila)2011May;50(5):383-90.
2
Sund-LevanderM,ForsbergC,WahrenLK.Normaloral,rectal,tympanicandaxillarybodytemperature
inadultmenandwomen:asystematicliteraturereview.ScandJCaringSci2002June;16(2):122-8.

Age Precision

Digital

Thermometer

PRT 2000

Age Precision

MC

Thermomètre

numérique

Downloaded from www.vandenborre.be

User manual

View the manual for the Braun Age Precision PRT 2000 here, for free. This manual comes under the category Thermometers and has been rated by 4 people with an average of a 8.8. This manual is available in the following languages: English. Do you have a question about the Braun Age Precision PRT 2000 or do you need help? Ask your question here

Need help?

Do you have a question about the Braun Age Precision PRT 2000 and the answer is not in the manual? Ask your question here. Provide a clear and comprehensive description of the problem and your question. The better your problem and question is described, the easier it is for other Braun Age Precision PRT 2000 owners to provide you with a good answer.

Debbue • 18-3-2022 No comments

Can I switch to Fahrenheit

Answer this question
Jayne Huddleston • 19-6-2022 No comments

I'm following the instructions to change it to Farenheit and it won't change

Answer this question
Pierrette • 24-4-2022 No comments

It just buzzes but does not turn on to take temperature. I annot turn off that sound either or the thermometer to try again.

Answer this question
Ian Paterson • 26-3-2022 No comments

how to keep it permentlyanly on one age group and I also do not get any sound ( beep) at any time. How to fix

Answer this question

Number of questions: 4

Braun Age Precision PRT 2000 specifications

Below you will find the product specifications and the manual specifications of the Braun Age Precision PRT 2000.

General
Brand Braun
Model Age Precision PRT 2000
Product Thermometer
Language English
Filetype manual_type_manual (PDF)

Questions & answers

Can't find the answer to your question in the manual? You may find the answer to your question in the FAQs about the Braun Age Precision PRT 2000 below.

Is your question not listed? Ask your question here

No results